Mechanical Integration without Window

For all of the diagrams in this page, please refer to the ConnectWare2 Slim integration document.

All primary dimensions are in millimeters.

Overall Dimensions

image-20240628-204257.png

PCB assembly

Install PCB on top of M3 or 4-40 standoffs minimum 4mm long. Recommend button head cap screws.

Cable Connections

Allow minimum 3” of space for cable bend radius. Cables should be strain relieved on the chassis to avoid connector stress.

Wi-Fi External Antenna

The external antenna is required for use with a PCB configured for external antenna.

The antenna cable connects to the PCB where shown. It is important to add strain relief to this cable nearby to the PCB to avoid damage. The cable diameter is 1.3mm. Locate the antenna within reach of the 1 meter cable. Loop excess cable with minimum 3” bend radius. Do not fold or bend the coaxial cable.

image-20240628-180936.png

The antenna end of the cable is a rear mount, front nut bulkhead type. A 0.25” or D style hole is required to mount the cable to the cabinet. The antenna is a screw on swivel style connection. Recommend shipping the antenna removed from the enclosure if it will be susceptible to damage during shipping and installation.

 

Thermal Consideration

Mechanical Integration with Window | Thermal Consideration

Product Nameplate Label

Mechanical Integration with Window | Product Nameplate Label