Install PCB on top of M3 or 4-40 standoffs minimum 4mm long. Recommend button head cap screws.
Cable Connections
Allow minimum 3” of space for cable bend radius. Cables should be strain relieved on the chassis to avoid connector stress.
...
The antenna end of the cable is a rear mount, front nut bulkhead type. A 0.25” or D style hole is required to mount the cable to the cabinet. The antenna is a screw on swivel style connection. Recommend shipping the antenna removed from the enclosure if it will be susceptible to damage during shipping and installation.
...
...
Thermal Consideration
The standard configurations without battery backup have a maximum operating temperature of 85°C.
With the battery backup option installed, the maximum operating temperature is 70°C.https://sitesage.atlassian.net/wiki/spaces/~62ffb98c2cbfba0566adcf5f/pages/483295367/Mechanical+Integration+with+Window#Thermal-Consideration