Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

View file
nameDOC-000052-03 REV C.pdf
Primary dimensions are in millimeters.

View file
nameDOC-000052-03.STEP
STEP Assembly Model

Overall Dimensions

...

Enclosure Preparation for Window Option

...

The window is mounted to the exterior wall with two M3 studs (item 2) and hex nuts. The PCB is installed above the window onto four M3x6mm standoffs (item 3) and screws. Use minimum 6mm standoffs provide adequate space for components under the PCB. Avoid using long standoffs in order to keep the antenna as close to the window as possible for wireless signal strength. The 27.89mm dimension is critical. It sets the location of the window to the PCB.

Solidworks STEP model for example cabinet wall.

View file
namecabinet_wall_asm.zipSTEP

...

Window Assembly

The window is clear, hard coated polycarbonate with scratch resistant coating. There is a decal on the inside surface. The external surface is washable. The 3D model and spare part number is

View file
name330-000014.STEP

Attach window to cabinet wall using two M3 hex nuts. Orient the window with the graphics facing out. Add a thin bead of silicone to the front side of the window for added water ingress protection if desired.

...

DOC-000052-03 for web page2.JPGImage Added

PCB Assembly with Window Option

The PCB

View file
name250-000052-01.step
is assembled on top of the window using four M3x6mm button head cap screws. Orient the PCB with connectors side out. Allow for 3.0” space under the connectors to allow for cable bend radius and disconnection. Secure cables to chassis to prevent strain on connectors.image-20240628-180745.pngImage Removed

...

Product Nameplate Label

The label supplied with the ConnectWare2 Slim kit contains necessary serial number, network address, and regulatory compliance information. The label dimensions are 63mm x 38mm

...