OKE implementation expects a hardcoded file name and file uploaded to OKC doesn’t match:
It’s commonly seen that developers hard code an expected file name for certain file types, e.g. firmware.bin, menu.json. If someone subsequently uploads a file to the OKC with a different name (e.g. firmwareV1-2-3.bin), the file will be downloaded to the OKE (and indeed the status shown in Open Kitchen will be ‘downloaded’), but it isn’t loaded into the system because of the name mismatch. We recommend avoiding this approach and to instead encode identifiable information in the file header. If not avoidable, then ensure the file uploaded to the OKC is correctly namedOld CWM firmware and/or CWL version: In CWM1 firmware earlier than PIC154/SPH145 and ConnectWare Library versions < 1.0.15, there was a bug in the fragmentation layer that caused messages of certain lengths to be dropped. This can cause a multitude of issues including download rewinds due to dropped fragments (ultimately ended in an aborted download), and files that do ‘successfully' download to the CWM but aren’t loaded into the OKE. If you encounter such issues, please ensure your CWM firmware and CWL versions are up to date.
File name + extension longer than 16 characters: the OKC now prevents this from happening, but it may still be possible to do with the simulators. The CWL has a 16 character limit on the file name including the extension. If this limit is exceeded, the CWM will download the fragments from the OKC but just throw them away. Please ensure file names are <= 16 characters including extension.
File Name + Version + Account ID not unique combination: Currently, there is a unique index in Open Kitchen Database that requires a combination of File Name - Version - Account ID to be unique even the uploaded file has been deleted. If Version does not have value entered by user, it will have timestamp value. However, user can enter Version for it to be used to match with equipment data for file transfer status. If this is the case, it may cause violation of unique File Name + Version + Account ID combo key. In this scenario, if a firmware file needs to be uploaded from the same Account, it needs to have unique File Name and Version (if input by user) every time it is uploaded even after it is deleted from Open Kitchen.
Connectware Module V2 uses low baud rate: Some likely scenarios are the following.
If a CWM2 reports the baud rate as 115200 in its heartbeat, it could be because OKE does not request a baud rate change to increase the RS232 baud rate from 115200 to 230400. CWM2 will accept the baud rate change request from the OKE over the 232 port. The OKE could put some temporary debug output in the CWL where it make the baud rate change requests and processed the baud rate change responses.
If the OKE was connected to a CWM1, and a CWM2 was swapped in without the OKE restarting, then the OKE will not request a baud rate speed increase. This is because the CWM1 cannot run faster than 115200 and informs the OKE that it does not support a speed increase. The OKE will no longer request a speed increase until the OKE’s CWL is restarted. Low baud rate on CWM2 can cause slow file transfer. The baud rate speed is independent of doing a file transfer. Therefore there is no file transfers increased until the CWM reports its baud rate at 230400, since it will never go faster than about 1 hour.
Does OKE run a build that does not change baud rate?
There are some hardware or cabling problem that causes the speed rate change to fail. For example, the speed increase takes effect, but the OKE and CWM cannot communicate successfully at that speed, and eventually revert back to 115200. It is expected that the CWM would sometimes report “baud”:230400 if this was the case.